The Normstahl LH608AIL loadhouse represents a cutting-edge solution for loading operations, integrating all essential components—leveler, shelter, and door—into a single, cohesive system. When paired with the Autodock bottom platform and the insulated cladding house, it forms a complete and self-sufficient dock loading system that enhances operational efficiency.
Placed outside the door opening of a warehouse or terminal, the operator will gain inside space advantages compared to a conventional, inside docking installation, in both new and existing buildings without any major building modifications.
Due to the thermal separation between building and docking unit, the Loadhouse can be used in temperature-controlled applications. The Normstahl LH608AIL loadhouse is a new insulated version with a very attractive appearance, specially developed to meet all requirements of architects, builders and operators. The outstanding feature is that the walls are made of insulated panels without a steel frame inside the loadhouse.
The smooth wall surfaces are washable and meet the requirements for cleanliness e.g. from the food industry. Underneath the roof section made of a steel frame with sheet cladding, a horizontal panel even provides a smooth ceiling. The inside surfaces of the loadhouse is like a closed box with no open spaces or protruding fixtures which can cause damage or injuries whilst keeping the birds and their nests’ away.
In summary, the Normstahl LH608AIL loadhouse is a state-of-the-art loading solution that combines efficiency, safety, and aesthetic appeal, making it an ideal choice for modern logistics operations.
The load house makes it possible to move the actual loading and unloading area outside the building and thereby releasing the corresponding floor area inside.
The Normstahl LH608AIL Loadhouse also forms a protective barrier between building and vehicle, contributing to energy savings and an improved working environment. Dock levelers and shelters can be integrated with the load house, together forming a complete Autodocksystem.
As there is no need for complicated concrete pit construction the total cost of the building is reduced.
Feature | Specification |
---|---|
Nominal length | 2450, 3000 mm |
Nominal width | 3300, 3500, 3600, 3750 mm |
Installation type | Single or multi installation |
Certification | Declaration of Performance according to EN1090 |
Snow load | 3,0 kN/m² according to EN1993 |
Wind load | 0,913 kN/m² |
Steel profiles | Galvanized steel |
Roof material thickness | 0,6 mm profiled steel sheet |